Emotron

 

Protection from damage and downtime | DRIVECONTROL

Soft starts and stops protect your equipment. Reduced start currents result in smaller fuses, cables and energy bills. Controlled stops eliminate the risk of water hammer and other costly damage.

A built-in shaft power monitor and a unique Load Curve Protection function protect your process by immediately detecting any situation that could cause inefficiency or damage. Early warnings and safety stops allow preventive action.

Energy savings and optimized operation | DRIVECONTROL

Emotron FDU regulates flow and pressure by continuously adapting motor speed. No energy wasted and no unnecessary equipment wear. A sleep function further reduces energy consumption by pausing the motor when it is not needed to be run. An automatic pump rinsing function increases efficiency.

Multiple pump or compressor control is a reliable and cost-efficient method of keeping a constant flow or pressure despite varying demands. Emotron FDU controls up to seven drives.

User-friendly and reliable operation | DRIVECONTROL

Operation parameters can be set in your own process units – m3/min, bar, Pascal etc. – making monitoring easier and more reliable. The removable control panel has a copy function for transferring settings to other Emotron FDU units. You can switch between local and remote control by the push of a key on the control panel. The virtual connection of logical functions, comparators and timers means no cables or external I/Os are required.

Cost-efficient and flexible installation | DRIVECONTROL

The compact standalone 2.5-250 A units are IP54 classified. The robust steel construction can be installed close to the application, which saves the cost of cabinets and long motor cables. The 300-1,500 A units can be mounted in compact Emotron-designed IP54 cabinets.

Simplified maintenance | DRIVECONTROL

Should a process problem occur a full status report will be generated. You can quickly identify the cause and take corrective measures. Maintenance is simplified thanks to a minimum of easy accessible mechanical parts and fold-out power modules.

Smooth starts reduce your costs| DRIVECONTROL

 

Efficient torque control ensures an ultra-smooth start with constant acceleration. Reduced start currents and mechanical stress means lower installation, energy and maintenance costs. Torque boost can be used to overcome initial torque peaks when starting, for example, a loaded crusher.

Protect your process and maximize efficiency| DRIVECONTROL

 

A built-in shaft power monitor protects your process from damage, downtime and inefficiency. It reacts immediately if a crusher is jammed, a pump is running dry or a fan filter is blocked. Any deviation from your selected load levels will result in a warning or a quick but smooth stop.


Smart stops – smooth or quick| DRIVECONTROL

 

Emotron MSF offers efficient solutions, whether the need is a smooth or a quick stops. A linear stop of a pump eliminates the risk of water hammer. No motor-controlled valves are needed. Built-in braking functionality ensures quick and safe stops of mills and saws without mechanical brakes.


Programmable inputs increase flexibility| DRIVECONTROL

Four programmable inputs offer great flexibility. The rotating direction of a fan can be controlled by programming two inputs for start left/right. No external PLC is required. You can connect an external alarm signal to stop the motor if a problem occurs. An analogue sensor can be connected directly to the Emotron MSF to control the start and stop levels of a pump.


Quick and cost-efficient installation| DRIVECONTROL

Installing an Emotron MSF is quick and cost-efficient. There is no need for the additional equipment often required – DC brakes, motor protection relays, mains failure relays, load monitors, meters, displays or switches. Everything you need is included in the Emotron MSF unit.

Emotron
Emotron

 

Efficient and protective starts and stops | DRIVECONTROL

Efficient and protective starts are ensured with Emotron VFX. Reduced start currents result in smaller fuses, cables and energy bills. Torque can be boosted to overcome initial peak loads. Integrated vector braking ensures quick and controlled stops, increasing productivity and safety.

 

Optimized operation and full control | DRIVECONTROL

The direct torque control reacts extremely quickly and eliminates disturbances due to abrupt load changes. A built-in shaft power monitor and a unique Load Curve Protection function protect your process by immediately detecting any situation that could cause inefficiency or damage. Early warnings and safety stops allow preventive action.

 

User-friendly and reliable operation | DRIVECONTROL

Operation parameters can be set in your own process units – m/sec, tons/hour, cycles/min etc. – making monitoring easier and more reliable. The removable control panel has a copy function for transferring settings to other Emotron VFX units. You can switch between local and remote control by the push of a key on the control panel. The virtual connection of logical functions, comparators and timers means no cables or external I/Os are required.

Cost-efficient and flexible installation | DRIVECONTROL

The compact standalone 2.5-250 A units are IP54 classified. The robust steel construction can be installed close to the application, which saves the cost of cabinets and long motor cables. The 300-1,500 A units can be mounted in compact Emotron-designed IP54 cabinets.

 

Simplified maintenance | DRIVECONTROL

Should a process problem occur a full status report will be generated. You can quickly identify the cause and take corrective measures. Maintenance is simplified thanks to a minimum of easy accessible mechanical parts and fold-out power modules.

Emotron

DRIVECONTROL